CVE intelligence and bounded remediation

CVE-2026-32937 — free5GC is an open source 5G core network

High CVSS 7.1

free5GC is an open source 5G core network. free5GC CHF prior to version 1.2.2 has an out-of-bounds slice access vulnerability in the CHF `nchf-convergedcharging` service. A valid authenticated request to PUT `/nchf-convergedcharging/v3/recharging/:ueId?ratingGroup=...` can trigger a server-side panic in `github.com/free5gc/chf/internal/sbi.(*Server).RechargePut(...)` due to an out-of-range slice access. In the reported runtime, Gin recovery converts the panic into HTTP 500, but the recharge path remains remotely panic-triggerable and can be abused repeatedly to degrade recharge functionality and flood logs. In deployments without equivalent recovery handling, this panic may cause more severe service disruption. free5GC CHF patches the issue. Some workarounds are available: Restrict access to the `nchf-convergedcharging` recharge endpoint to strictly trusted NF callers only; apply rate limiting or network ACLs in front of the CHF SBI interface to reduce repeated panic-trigger attempts; if the recharge API is not required, temporarily disable or block external reachability to this route; and/or ensure panic recovery, monitoring, and alerting are enabled.

Severity
High
CVSS
7.1 (4.0)
Published
2026-03-20
CISA KEV
Not currently listed
Ecosystem
software/application
Weaknesses
CWE-129

Affected products

  • free5gc / free5gc

Matched remediation archetype

Buffer bounds, memory safety, and memory corruption

This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.

Check exposure

  • Identify affected native-code versions, build flags, architectures, parsers, codecs, drivers, and input paths in all shipped artifacts.
  • Determine whether untrusted data reaches the affected routine and the process privilege, sandbox, and network exposure.
  • Confirm statically linked, vendored, firmware, and platform-provided copies, not only package-manager records.

Remediate safely

  • Apply the maintained upstream correction or replace the affected component, then rebuild every dependent artifact from clean inputs.
  • Adopt bounds-checked interfaces, validated sizes and integer conversions, clear ownership, and memory-safe components where practical.
  • Enable supported compiler and runtime hardening and add sanitized tests and fuzz regression seeds derived from non-weaponized fixtures.

Authoritative sources

Complete CVE record and remediation plan

The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.