CVE intelligence and bounded remediation

CVE-2024-2602 — Schneider-Electric Foxrtu Station security vulnerability

High CVSS 7.8

CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could result in remote code execution when an authenticated user executes a saved project file that has been tampered by a malicious actor.

Severity
High
CVSS
7.8 (3.1)
Published
2024-07-11
CISA KEV
Not currently listed
Ecosystem
software/application
Weaknesses
CWE-22

Affected products

  • schneider-electric / foxrtu_station

Matched remediation archetype

Path traversal, unsafe upload, and file handling

This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.

Check exposure

  • Trace untrusted filenames, archive entries, URLs, and path segments into read, write, include, extraction, and upload operations.
  • Identify filesystem roots, mount permissions, symbolic-link behavior, archive handling, and whether uploaded content is web-accessible or executable.
  • Review canonicalization and containment checks across supported operating systems and storage backends.

Remediate safely

  • Generate server-side storage identifiers and resolve paths beneath a fixed root using filesystem-aware containment checks.
  • Reject absolute, parent-relative, alternate-separator, device, link, and archive entries that escape the intended root.
  • Store uploads outside executable or served paths, validate type and size, and use private atomic temporary files.

Authoritative sources

Complete CVE record and remediation plan

The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.