CVE intelligence and bounded remediation
CVE-2024-23920 — Chargepoint Home Flex Nema 14-50 Plug Firmware security vulnerability
High
CVSS 8.8
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the onboardee module. The issue results from improper access control. An attacker can leverage this vulnerability to execute code in the context of root.
- Severity
- High
- CVSS
- 8.8 (3.1)
- Published
- 2025-01-31
- CISA KEV
- Not currently listed
- Ecosystem
- operating-system
- Weaknesses
- CWE-284
Affected products
- chargepoint / home_flex_nema_14-50_plug_firmware
- chargepoint / home_flex_hardwired_firmware
- chargepoint / home_flex_nema_6-50_plug_firmware
Matched remediation archetype
Authorization bypass, IDOR, and cross-tenant access
This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.
Check exposure
- Map object and action authorization checks across API, UI, batch, import/export, and background-job paths.
- Identify tenant, ownership, role, and policy boundaries for affected resources and administrative operations.
- Use synthetic fixtures to compare intended access matrices without accessing another user's real data.
Remediate safely
- Enforce server-side authorization at each resource access and state transition using the authenticated principal and trusted tenant context.
- Scope data queries by tenant and ownership; treat client-supplied identifiers, roles, and policy claims as untrusted.
- Add deny-by-default policy tests for horizontal and vertical access across every affected transport.
Authoritative sources
Complete CVE record and remediation plan
The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.