CVE intelligence and bounded remediation

CVE-2023-4291 — Frauscher Frauscher Diagnostic System 101 security vulnerability

Critical CVSS 9.8

Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.

Severity
Critical
CVSS
9.8 (3.1)
Published
2023-09-21
CISA KEV
Not currently listed
Ecosystem
software/application
Weaknesses
CWE-94

Affected products

  • frauscher / frauscher_diagnostic_system_101

Showing 1 representative product identities from 2 source matches. Confirm exact affected versions with the linked vendor and NVD evidence.

Matched remediation archetype

Command, code, expression, and template injection

This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.

Check exposure

  • Trace untrusted values to process execution, interpreters, evaluators, template engines, dynamic imports, and administrative scripting features.
  • Determine whether the affected path is reachable across each trust boundary and which service account or host privilege it inherits.
  • Review configuration for optional execution features, unsafe compatibility modes, and shell invocation.

Remediate safely

  • Replace string-built commands or evaluated code with fixed operations and structured argument APIs that do not invoke a shell.
  • Use strict allowlists for operation identifiers and reject unexpected input before it reaches any interpreter.
  • Update the affected component and add inert regression tests covering metacharacters, encoding variants, and alternate request paths.

Authoritative sources

Complete CVE record and remediation plan

The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.