CVE intelligence and bounded remediation
CVE-2023-0444 — A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a
High
CVSS 8.8
A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator.
- Severity
- High
- CVSS
- 8.8 (3.1)
- Published
- 2023-01-26
- CISA KEV
- Not currently listed
- Ecosystem
- software/application
Affected products
- deltaww / infrasuite_device_master / 00.00.02a
Matched remediation archetype
Privilege escalation and unsafe privilege management
This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.
Check exposure
- Map service accounts, operating-system identities, roles, capabilities, impersonation, set-user transitions, and administrative helper paths.
- Determine whether untrusted users or lower-privilege processes can reach the affected transition or modify inputs it trusts.
- Review file, socket, registry, device, job, container, and cloud-role permissions used before and after privilege changes.
Remediate safely
- Apply the supported fix and redesign privileged operations as a minimal, authenticated, allowlisted interface.
- Drop privileges before processing untrusted input, verify the drop succeeds, and remove unnecessary roles, capabilities, and write permissions.
- Validate ownership and permissions at time of use and add explicit lower-to-higher privilege boundary tests.