CVE intelligence and bounded remediation
CVE-2022-37300 — Schneider-Electric Ecostruxure Control Expert security vulnerability
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
- Severity
- Critical
- CVSS
- 9.8 (3.1)
- Published
- 2022-09-12
- CISA KEV
- Not currently listed
- Ecosystem
- software/application
- Weaknesses
- CWE-640
Affected products
- schneider-electric / ecostruxure_control_expert
- schneider-electric / ecostruxure_process_expert
- schneider-electric / modicon_m340_bmxp341000_firmware
- schneider-electric / modicon_m340_bmxp342000_firmware
- schneider-electric / modicon_m340_bmxp342010_firmware
- schneider-electric / modicon_m340_bmxp3420102_firmware
Matched remediation archetype
General vulnerability remediation
This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.
Check exposure
- Confirm the affected component, deployment paths, reachable interfaces, and enabled features from inventories and configuration, without probing production destructively.
- Compare the advisory's affected conditions with the repository lockfiles, build manifests, artifacts, and runtime inventory.
- Identify data sensitivity, trust boundaries, and privilege level for every confirmed affected deployment.
Remediate safely
- Apply a vendor-supported fix or remove the affected component or feature; record the selected change and its source in the repository.
- Update direct and transitive dependency locks, generated artifacts, deployment manifests, and asset inventories together.
- Add a regression test for the documented unsafe condition using inert inputs and preserve rollback instructions.
Authoritative sources
Complete CVE record and remediation plan
The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.