CVE intelligence and bounded remediation

CVE-2021-27384 — A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl

Critical CVSS 9.8

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary…

Severity
Critical
CVSS
9.8 (3.1)
Published
2021-05-12
CISA KEV
Not currently listed
Ecosystem
software/application
Weaknesses
CWE-788

Affected products

  • siemens / simatic_wincc_runtime_advanced
  • siemens / simatic_wincc_runtime_advanced / 16
  • siemens / sinamics_sh150_firmware
  • siemens / sinamics_sm150i_firmware
  • siemens / sinamics_gh150_firmware
  • siemens / sinamics_gl150_firmware

Showing 6 representative product identities from 129 source matches. Confirm exact affected versions with the linked vendor and NVD evidence.

Matched remediation archetype

Buffer bounds, memory safety, and memory corruption

This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.

Check exposure

  • Identify affected native-code versions, build flags, architectures, parsers, codecs, drivers, and input paths in all shipped artifacts.
  • Determine whether untrusted data reaches the affected routine and the process privilege, sandbox, and network exposure.
  • Confirm statically linked, vendored, firmware, and platform-provided copies, not only package-manager records.

Remediate safely

  • Apply the maintained upstream correction or replace the affected component, then rebuild every dependent artifact from clean inputs.
  • Adopt bounds-checked interfaces, validated sizes and integer conversions, clear ownership, and memory-safe components where practical.
  • Enable supported compiler and runtime hardening and add sanitized tests and fuzz regression seeds derived from non-weaponized fixtures.

Authoritative sources

Complete CVE record and remediation plan

The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.