CVE intelligence and bounded remediation
CVE-2020-27738 — Siemens Simotics Connect 400 Firmware security vulnerability
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.
- Severity
- High
- CVSS
- 7.4 (3.1)
- Published
- 2021-04-22
- CISA KEV
- Not currently listed
- Ecosystem
- software/application
- Weaknesses
- CWE-788, CWE-119
Affected products
- siemens / simotics_connect_400_firmware
- siemens / nucleus_net
- siemens / nucleus_readystart_v3
- siemens / nucleus_readystart_v4
- siemens / nucleus_source_code
Matched remediation archetype
Buffer bounds, memory safety, and memory corruption
This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.
Check exposure
- Identify affected native-code versions, build flags, architectures, parsers, codecs, drivers, and input paths in all shipped artifacts.
- Determine whether untrusted data reaches the affected routine and the process privilege, sandbox, and network exposure.
- Confirm statically linked, vendored, firmware, and platform-provided copies, not only package-manager records.
Remediate safely
- Apply the maintained upstream correction or replace the affected component, then rebuild every dependent artifact from clean inputs.
- Adopt bounds-checked interfaces, validated sizes and integer conversions, clear ownership, and memory-safe components where practical.
- Enable supported compiler and runtime hardening and add sanitized tests and fuzz regression seeds derived from non-weaponized fixtures.
Authoritative sources
Complete CVE record and remediation plan
The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.