CVE-2020-27737 — Siemens Simotics Connect 400 Firmware security vulnerability

Medium CVSS 6.5

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.

Severity
Medium
CVSS
6.5 (3.1)
Published
2021-04-22
CISA KEV
Not currently listed
Ecosystem
software/application
Weaknesses
CWE-125

Affected products

  • siemens / simotics_connect_400_firmware
  • siemens / nucleus_net
  • siemens / nucleus_readystart_v3
  • siemens / nucleus_readystart_v4
  • siemens / nucleus_source_code

Matched remediation archetype

Buffer bounds, memory safety, and memory corruption

This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.

Check exposure

  • Identify affected native-code versions, build flags, architectures, parsers, codecs, drivers, and input paths in all shipped artifacts.
  • Determine whether untrusted data reaches the affected routine and the process privilege, sandbox, and network exposure.
  • Confirm statically linked, vendored, firmware, and platform-provided copies, not only package-manager records.

Remediate safely

  • Apply the maintained upstream correction or replace the affected component, then rebuild every dependent artifact from clean inputs.
  • Adopt bounds-checked interfaces, validated sizes and integer conversions, clear ownership, and memory-safe components where practical.
  • Enable supported compiler and runtime hardening and add sanitized tests and fuzz regression seeds derived from non-weaponized fixtures.