CVE intelligence and bounded remediation

CVE-2020-12034 — Rockwellautomation Eds Subsystem security vulnerability

High CVSS 8.2

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.

Severity
High
CVSS
8.2 (3.1)
Published
2020-05-20
CISA KEV
Not currently listed
Ecosystem
software/application
Weaknesses
CWE-89

Affected products

  • rockwellautomation / eds_subsystem
  • rockwellautomation / rslinx
  • rockwellautomation / rslinx_enterprise / 6.00.00
  • rockwellautomation / rslinx_enterprise / 6.10.00
  • rockwellautomation / rslinx_enterprise / 6.11.00
  • rockwellautomation / rsnetworx

Showing 6 representative product identities from 7 source matches. Confirm exact affected versions with the linked vendor and NVD evidence.

Matched remediation archetype

SQL and data-query injection

This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.

Check exposure

  • Trace request, message, file, and stored values into SQL, ORM query fragments, filters, sort expressions, and other data-query languages.
  • Inventory database roles, reachable schemas, multi-tenant boundaries, and whether stacked or administrative operations are enabled.
  • Check both direct queries and second-order use of previously stored values.

Remediate safely

  • Use parameterized queries or safe query builders for all values; map identifiers and operators through explicit allowlists.
  • Remove raw query concatenation and give the application account only the tables and operations it requires.
  • Update affected data-access components and add regression tests for query structure preservation with inert edge-case inputs.

Authoritative sources

Complete CVE record and remediation plan