CVE intelligence and bounded remediation
CVE-2019-10916 — Siemens Simatic Pcs 7 security vulnerability
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory p…
- Severity
- High
- CVSS
- 9 (2.0)
- Published
- 2019-05-14
- CISA KEV
- Not currently listed
- Ecosystem
- software/application
- Weaknesses
- CWE-89
Affected products
- siemens / simatic_pcs_7
- siemens / simatic_pcs_7 / 8.1
- siemens / simatic_pcs_7 / 8.2
- siemens / simatic_pcs_7 / 9.0
- siemens / simatic_wincc
- siemens / simatic_wincc / 7.3
Matched remediation archetype
SQL and data-query injection
This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.
Check exposure
- Trace request, message, file, and stored values into SQL, ORM query fragments, filters, sort expressions, and other data-query languages.
- Inventory database roles, reachable schemas, multi-tenant boundaries, and whether stacked or administrative operations are enabled.
- Check both direct queries and second-order use of previously stored values.
Remediate safely
- Use parameterized queries or safe query builders for all values; map identifiers and operators through explicit allowlists.
- Remove raw query concatenation and give the application account only the tables and operations it requires.
- Update affected data-access components and add regression tests for query structure preservation with inert edge-case inputs.
Authoritative sources
Complete CVE record and remediation plan
The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.