CVE-2018-4844 — Siemens Simatic Wincc Oa Ui security vulnerability
A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
- Severity
- Medium
- CVSS
- 6.7 (3.1)
- Published
- 2018-03-20
- CISA KEV
- Not currently listed
- Ecosystem
- software/application
- Weaknesses
- CWE-284, CWE-269
Affected products
- siemens / simatic_wincc_oa_ui
Matched remediation archetype
Privilege escalation and unsafe privilege management
This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.
Check exposure
- Map service accounts, operating-system identities, roles, capabilities, impersonation, set-user transitions, and administrative helper paths.
- Determine whether untrusted users or lower-privilege processes can reach the affected transition or modify inputs it trusts.
- Review file, socket, registry, device, job, container, and cloud-role permissions used before and after privilege changes.
Remediate safely
- Apply the supported fix and redesign privileged operations as a minimal, authenticated, allowlisted interface.
- Drop privileges before processing untrusted input, verify the drop succeeds, and remove unnecessary roles, capabilities, and write permissions.
- Validate ownership and permissions at time of use and add explicit lower-to-higher privilege boundary tests.