CVE intelligence and bounded remediation

CVE-2018-13813 — Siemens Simatic Hmi Comfort Panels Firmware security vulnerability

High CVSS 8.1

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Severity
High
CVSS
8.1 (3.0)
Published
2018-12-13
CISA KEV
Not currently listed
Ecosystem
software/application
Weaknesses
CWE-601

Affected products

  • siemens / simatic_hmi_comfort_panels_firmware
  • siemens / simatic_hmi_comfort_outdoor_panels_firmware
  • siemens / simatic_hmi_ktp_mobile_panels_ktp400f_firmware
  • siemens / simatic_hmi_ktp_mobile_panels_ktp700_firmware
  • siemens / simatic_hmi_ktp_mobile_panels_ktp700f_firmware
  • siemens / simatic_hmi_ktp_mobile_panels_ktp900_firmware

Showing 6 representative product identities from 13 source matches. Confirm exact affected versions with the linked vendor and NVD evidence.

Matched remediation archetype

General vulnerability remediation

This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.

Check exposure

  • Confirm the affected component, deployment paths, reachable interfaces, and enabled features from inventories and configuration, without probing production destructively.
  • Compare the advisory's affected conditions with the repository lockfiles, build manifests, artifacts, and runtime inventory.
  • Identify data sensitivity, trust boundaries, and privilege level for every confirmed affected deployment.

Remediate safely

  • Apply a vendor-supported fix or remove the affected component or feature; record the selected change and its source in the repository.
  • Update direct and transitive dependency locks, generated artifacts, deployment manifests, and asset inventories together.
  • Add a regression test for the documented unsafe condition using inert inputs and preserve rollback instructions.

Authoritative sources

Complete CVE record and remediation plan