CVE intelligence and bounded remediation
CVE-2016-8377 — An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701
High
CVSS 8
An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack buffer overflow. This causes an exploitable Structured Exception Handler (SEH) overwrite condition that may allow remote code execution.
- Severity
- High
- CVSS
- 8 (3.1)
- Published
- 2017-02-13
- CISA KEV
- Not currently listed
- Ecosystem
- operating-system
- Weaknesses
- CWE-119
Affected products
- fatek / plc_winproladder_firmware / 3.11
Matched remediation archetype
Buffer bounds, memory safety, and memory corruption
This catalog composition supplies bounded fallback guidance. Explicitly reviewed curated workflows load with the complete record below.
Check exposure
- Identify affected native-code versions, build flags, architectures, parsers, codecs, drivers, and input paths in all shipped artifacts.
- Determine whether untrusted data reaches the affected routine and the process privilege, sandbox, and network exposure.
- Confirm statically linked, vendored, firmware, and platform-provided copies, not only package-manager records.
Remediate safely
- Apply the maintained upstream correction or replace the affected component, then rebuild every dependent artifact from clean inputs.
- Adopt bounds-checked interfaces, validated sizes and integer conversions, clear ownership, and memory-safe components where practical.
- Enable supported compiler and runtime hardening and add sanitized tests and fuzz regression seeds derived from non-weaponized fixtures.
Authoritative sources
Complete CVE record and remediation plan
The detailed catalog view below loads this exact record, its source evidence, and the full seven-phase agentic change plan.